Scaps Driver Download
- Scaps Driver Download Torrent
- Scaps Driver Download
- Scaps Driver Download Free
- Scaps Driver Download Windows 7
Figure 63: USC-2 Driver Settings Dialog
Correction: Opens the Correction Settings Dialog (see below).
Marking on the Fly: Opens the MOTF Settings Dialog (see below).
Analog In: Opens the Analog In Settings Dialog (see below).
Test Laserports:
Download PhotoScape for Windows now from Softonic: 100% safe and virus free. More than 47202 downloads this month. Download PhotoScape latest version 2021. As long as the client does not use SCAPS Software for commercial purposes, but only for purposes of presentation or evaluation, he is entitled to download, copy and install a demo version of SCAPS Software, which at the sole discretion of SCAPS can contain functions of the full version by granting a password for a limited period, without. Installing SAMLight: Run scsamsetupv3XXYYYYMMDD.exe and follow the instructions. As default, the SCAPS software will be installed into the folder C: scaps sam2d.In the following text, SCAPS is a placeholder of the software installation path.
DAC: A value between 0 and 4095 will be set on the output by clicking 'Apply Now'. The radio buttons (2.5 V, 5 V and 10 V) are used to set the reference voltage of DAC A and DAC B.
8-Bit: A value between 0 and 255 will be set on the output by clicking 'Apply Now'.
Mode: The radio buttons define the used Laser mode. 'Q-Switch after FPK' defines that the Q-Switch (LaserA) starts to pulse after a single pulse at the LaserB port. 'Invert', each Laser signal can be inverted separately.
The laser signals can be inverted only with sc_setup.exe. In SAMLight the check boxes are grayed out. |
Test IO: The 'Output' check boxes can be used to set OptoOut[0..5], DigiOut[0..9] and StepperOut[0..5]. The 'Input' check boxes can be used to display OptoIn[0..5], DigiIn[0..9] and StepperIn[0..2]. The 'Invert' check boxes are used to invert a single input or output.
Temperature [°C]: Shows the current USC-2 temperature in degree Celsius
Laserport: The radio buttons define which port to use for Laser power control. The 'Invert' flag can be used to invert the laser port, this means 0 = 100% and 255 = 0% power. The power ramp can be activated by the 'Up' and 'Down' flag, the gradient of the ramp has to be between 0 and 255.
Combine with LaserGate: If DAC A or DAC B is chosen under Laserport it is possible to turn off the laser power signal with the closing of the LaserGate. If LaserGate is going down DAC A or DAC B will also go down to 0. If the checkbox 'Set DAC B' is activated the DAC A will not go to 0 when LaserGate is going down but it will be set to the value that is defined under Test Laser ports -> DAC B.
StandBy: If enabled, a standby frequency and a pulse length can be defined.
Optimize PolyDelay: If selected the length of the polygon delay gets varied depending on the angle between two successive vectors. This feature becomes active when downloading a job to the flash. The Optimized PolyDelay can't be computed in StandAloneMode.
Pixel Grayscale: 'PixelAM': enables Amplitude Modulation. 'PixelPWM': enables Pulse Width Modulation. 'Laserport': if checked the selected Laserport gets used for the output of PixelAM, else port DA2 is taken.
Store: Store the settings to the USC-2 EPCS (this is necessary for stand-alone operation).
When pressing 'Store' all settings described above are stored to the USC-2. Make sure that the settings fit to the Laser and other machinery. |
Save Trail File: Saves the USC-2 trail file to <SCAPS>intermed. The file name corresponds to sc_usc2_trail_head_x.txt, where x stands for the head number.
Figure 64: USC-2 Correction Settings Dialog
Use the 'Browse' button to open the desired correction file. The Head can be selected from the drop down menu.
It is possible to use different correction files for both Heads! The following described settings can be made for each Head separately. |
Enable: Enables the selected Head
Offset [bits]: The offset values are thought to compensate slightly X/Y offset errors to achieve the theoretical midpoint of the scanner field. Global offset errors which have the same deviation in X and Y direction should be corrected by changing the field X/Y min values in the Field edit group.
Gain: The gain values are thought to compensate slightly X/Y gain errors to archive a quadratic field.
Rotation: The scanner output will be rotated counterclockwise by this angle.
Z Correction: 'Settings': opens the next dialog, where the settings for Z correction can be edited.
Figure 65: USC-2 MOTF Settings Dialog
Multiplier: Type in the preferred MOTF factor and select the unit from the drop down menu.
Distance: The current distance will be displayed here.
Reset: Resets the displayed distance.
Channel: The direction, on which the encoder input takes effect, can be selected via the radio buttons.
It is possible to use both encoder inputs for the same direction! |
Simulation: Enables simulation, therefore the encoder signals are generated by the USC-2 itself.
Figure 66: USC-2 Analog In Settings Dialog
Scaps Driver Download Torrent
Currently, the Analog In can be used to move the scanner output in X and Y direction.
Value: Shows the applied voltage in Volts.
Offset: 'Center': defines, which voltage has to be applied without causing a movement.
If this value is bigger than zero, the output can be moved in +/- direction. |
Scaps Driver Download
Gain: Defines, how many mm the output will be moved per Volt.
SCC Tool Availability
The SCC Tool is only available on DoD Cyber Exchange NIPR. To access DoD Cyber Exchange NIPR, click on Login with CAC at the top right of the screen and use your CAC with DoD Certificates to access this content.
Scaps Driver Download Free
SCAP 1.2 Content
Scaps Driver Download Windows 7
Title | Size | Updated |
---|---|---|
Canonical Ubuntu 18.04 STIG Benchmark - Ver 2, Rel 1 | 50.4 KB | 22 Jan 2021 |
Red Hat Enterprise Linux 6 STIG Benchmark - Ver 2, Rel 2 | 93.91 KB | 22 Jan 2021 |
Red Hat Enterprise Linux 7 STIG Benchmark - Ver 3, Rel 2 | 96.39 KB | 22 Jan 2021 |
Mozilla Firefox Windows STIG Benchmark - Ver 5, Rel 1 | 13.17 KB | 22 Jan 2021 |
Canonical Ubuntu 16.04 STIG Benchmark - Ver 2, Rel 2 | 55.76 KB | 22 Jan 2021 |
Oracle Linux 7 STIG Benchmark - Ver 2, Rel 2 | 87.42 KB | 22 Jan 2021 |
SUSE Linux Enterprise Server 12 STIG Benchmark - Ver 2, Rel 2 | 49.44 KB | 22 Jan 2021 |
Mozilla Firefox for RHEL STIG Benchmark - Ver 5, Rel 1 | 12.54 KB | 22 Jan 2021 |
Microsoft .Net Framework 4 STIG Benchmark - Ver 2, Rel 1 | 8.44 KB | 22 Jan 2021 |
Solaris 10 SPARC STIG Benchmark - Ver 2, Rel 2 | 78.95 KB | 22 Jan 2021 |
Mozilla Firefox STIG Configuration Files - Ver 5, Rel 1 | 1.59 KB | 22 Jan 2021 |
Google Chrome for Windows STIG Benchmark - Ver 2, Rel 2 | 23.22 KB | 22 Jan 2021 |
Solaris 10 x86 STIG Benchmark - Ver 2, Rel 2 | 80.17 KB | 22 Jan 2021 |
Solaris 11 X86 STIG Benchmark - Ver 2, Rel 2 | 40.3 KB | 22 Jan 2021 |
Solaris 11 SPARC STIG Benchmark - Ver 2, Rel 2 | 39.27 KB | 22 Jan 2021 |
Red Hat Enterprise Linux 8 Draft Benchmark Comment Matrix | 30.54 KB | 06 Jan 2021 |
Red Hat Enterprise Linux 8 Draft STIG Benchmark - Ver 1, Rel 0.3 | 48.15 KB | 06 Jan 2021 |
Microsoft Windows 10 STIG Benchmark - Ver 2, Rel 1 | 100.2 KB | 02 Dec 2020 |
Microsoft Windows Server 2012 and 2012 R2 DC STIG Benchmark - Ver 3, Rel 1 | 123.77 KB | 02 Dec 2020 |
Microsoft Windows Server 2012 and 2012 R2 MS STIG Benchmark - Ver 3, Rel 1 | 123.05 KB | 02 Dec 2020 |
Microsoft Windows Defender Antivirus STIG Benchmark - Ver 2, Rel 1 | 23.19 KB | 02 Dec 2020 |
Microsoft Windows Server 2016 STIG Benchmark - Ver 2, Rel 1 | 91.27 KB | 02 Dec 2020 |
Microsoft Windows Server 2019 STIG Benchmark - Ver 2, Rel 1 | 98.18 KB | 02 Dec 2020 |
Juniper SRX SG STIG for Ansible - Ver 1, Rel 1 | 368.27 KB | 19 Nov 2020 |
Adobe Acrobat Reader DC Classic Track STIG Benchmark - Ver 2, Rel 1 | 10.95 KB | 26 Oct 2020 |
Microsoft Internet Explorer 11 STIG Benchmark - Ver 1, Rel 15 | 61.54 KB | 28 Jul 2020 |
McAfee VirusScan 8.8 Local Client STIG Benchmark - Ver 1, Rel 2 | 37.54 KB | 31 Oct 2019 |
McAfee VirusScan 8.8 Managed Client STIG Benchmark - Ver 1, Rel 3 | 25.45 KB | 31 Oct 2019 |
Adobe Acrobat Reader DC Continuous Track STIG Benchmark - Ver 1, Rel 5 | 10.48 KB | 26 Jul 2019 |
Microsoft Windows Firewall STIG Benchmark - Ver 1, Rel 7 | 12.75 KB | 01 Dec 2018 |